Torvinen (2018) - EPMA-WDS raw data for sherd samples
Part of the Collective Social Identification at La Quemada, Zacatecas, Mexico project
Creator(s): Andrea Torvinen
Year: 2018
Summary
These elemental data were collected using the Quantitative Wavelength Dispersive Spectroscopy technique with the JEOL JXA-8530F Electron Probe Microanalyzer (EPMA-WDS) at the John M. Crowley Center for High Resolution Electron Microscopy at Arizona State University supervised by Dr. Axel Wittmann.
Based on the methodology developed by Abbott and Lack (2013), a series of five assays were run per sample at 300X magnification in a relatively inclusion free area of clay matrix (spot area = 20 um) and the weight percentages of eight elements (K, Al, Na, Ti, Ca, Si, Mg, and Fe) were measured using a set of five wavelength-dispersive spectrometers. Data on six minor elements (Mn, Cr, S, Ni, Co, and O) were also collected but not analyzed because the precision of their measurement is typically insufficient for statistical analysis. Precision of the results was regularly checked against known abundances of these elements in standard reference materials using the same analytical protocol. The elemental measurements for each assay were standardized using the JEOL system software and output for analysis.
Abbott, David R. and Andrew D. Lack (2013) Prehistoric Warfare in Central Arizona, USA: Assessing Its Scale with Ceramic Chemistry. Geoarchaeology 28(2):147-169.
Cite this Record
Torvinen (2018) - EPMA-WDS raw data for sherd samples. Andrea Torvinen. 2018 ( tDAR id: 458202) ; doi:10.6067/XCV8458202
Data Set Structure
Table Information: Torvinen (2018) - EPMA-WDS sherd data
Column Name | Data Type | Type | Category | Coding Sheet | Ontology | Search |
---|---|---|---|---|---|---|
Ti CDL99 | detection limits based on counting statistics at the 99th percentile confidence limit in oxide weight-percent | |||||
DOUBLE | Uncoded Value | uncategorized | none | none | true | |
Ni CDL99 | detection limits based on counting statistics at the 99th percentile confidence limit in oxide weight-percent | |||||
BIGINT | Uncoded Value | uncategorized | none | none | true | |
Fe CDL99 | detection limits based on counting statistics at the 99th percentile confidence limit in oxide weight-percent | |||||
DOUBLE | Uncoded Value | uncategorized | none | none | true | |
S CDL99 | detection limits based on counting statistics at the 99th percentile confidence limit in oxide weight-percent | |||||
BIGINT | Uncoded Value | uncategorized | none | none | true | |
Si CDL99 | detection limits based on counting statistics at the 99th percentile confidence limit in oxide weight-percent | |||||
DOUBLE | Uncoded Value | uncategorized | none | none | true | |
TOTAL | total oxide-weight per cent | |||||
DOUBLE | Measurement (other) | Ceramic : Composition | none | none | true | |
Mg CDL99 | detection limits based on counting statistics at the 99th percentile confidence limit in oxide weight-percent | |||||
DOUBLE | Uncoded Value | uncategorized | none | none | true | |
Mn CDL99 | detection limits based on counting statistics at the 99th percentile confidence limit in oxide weight-percent | |||||
DOUBLE | Uncoded Value | uncategorized | none | none | true | |
Date | date the sample was analyzed | |||||
DATE | Uncoded Value | Other : Date Created | none | none | true | |
Na CDL99 | detection limits based on counting statistics at the 99th percentile confidence limit in oxide weight-percent | |||||
DOUBLE | Uncoded Value | uncategorized | none | none | true | |
Co CDL99 | detection limits based on counting statistics at the 99th percentile confidence limit in oxide weight-percent | |||||
BIGINT | Uncoded Value | uncategorized | none | none | true | |
Cr CDL99 | detection limits based on counting statistics at the 99th percentile confidence limit in oxide weight-percent | |||||
DOUBLE | Uncoded Value | uncategorized | none | none | true | |
Ca CDL99 | detection limits based on counting statistics at the 99th percentile confidence limit in oxide weight-percent | |||||
DOUBLE | Uncoded Value | uncategorized | none | none | true | |
Al CDL99 | detection limits based on counting statistics at the 99th percentile confidence limit in oxide weight-percent | |||||
DOUBLE | Uncoded Value | uncategorized | none | none | true | |
Column #19 | left intentionally blank | |||||
BIGINT | Uncoded Value | uncategorized | none | none | true | |
CoO | measurement units are oxide-weight per cent | |||||
BIGINT | Measurement (other) | Ceramic : Composition | none | none | true | |
Cr2O3 | measurement units are oxide-weight per cent | |||||
DOUBLE | Measurement (other) | Ceramic : Composition | none | none | true | |
MnO | measurement units are oxide-weight per cent | |||||
DOUBLE | Measurement (other) | Ceramic : Composition | none | none | true | |
Al2O3 | measurement units are oxide-weight per cent | |||||
DOUBLE | Measurement (other) | Ceramic : Composition | none | none | true | |
Na2O | measurement units are oxide-weight per cent | |||||
DOUBLE | Measurement (other) | Ceramic : Composition | none | none | true | |
TiO2 | measurement units are oxide-weight per cent | |||||
DOUBLE | Measurement (other) | Ceramic : Composition | none | none | true | |
CaO | measurement units are oxide-weight per cent | |||||
DOUBLE | Measurement (other) | Ceramic : Composition | none | none | true | |
MgO | measurement units are oxide-weight per cent | |||||
DOUBLE | Measurement (other) | Ceramic : Composition | none | none | true | |
SAMPLE | sample number | |||||
VARCHAR | Uncoded Value | Other : ID | none | none | true | |
K2O | measurement units are oxide-weight per cent | |||||
DOUBLE | Measurement (other) | Ceramic : Composition | none | none | true | |
Column #2 | VARCHAR | Uncoded Value | uncategorized | none | none | true |
K CDL99 | detection limits based on counting statistics at the 99th percentile confidence limit in oxide weight-percent | |||||
DOUBLE | Uncoded Value | uncategorized | none | none | true | |
FeO | measurement units are oxide-weight per cent | |||||
DOUBLE | Measurement (other) | Ceramic : Composition | none | none | true | |
O | measurement units are oxide-weight per cent | |||||
DOUBLE | Measurement (other) | Ceramic : Composition | none | none | true | |
NiO | measurement units are oxide-weight per cent | |||||
BIGINT | Measurement (other) | Ceramic : Composition | none | none | true | |
SO3 | measurement units are oxide-weight per cent | |||||
BIGINT | Measurement (other) | Ceramic : Composition | none | none | true | |
SiO2 | measurement units are oxide-weight per cent | |||||
DOUBLE | Measurement (other) | Ceramic : Composition | none | none | true |
Keywords
Investigation Types
Archaeological Overview
•
Data Recovery / Excavation
General
Electron Microprobe Analysis
•
Electron Probe Microanalyzer - Wavelength Dispersive Spectroscopy (EPMA-WDS)
Geographic Keywords
Malpaso Valley
•
Northwest Mexico
•
Zacatecas (State / Territory)
•
Zacatecas region
Temporal Keywords
Classic
•
Epiclassic
•
Postclassic
Temporal Coverage
Calendar Date: 600 to 800 (CE)
Spatial Coverage
min long: -105.941; min lat: 20.633 ; max long: -100.865; max lat: 24.807 ;
Individual & Institutional Roles
Contact(s): Andrea Torvinen
Principal Investigator(s): Andrea Torvinen; Ben Nelson
Source Collections
La Quemada-Malpaso Valley Archaeological Project ceramic assemblage
File Information
Name | Size | Creation Date | Date Uploaded | Access | |
---|---|---|---|---|---|
Torvinen--2018----EPMA-WDS-sherd-data.xlsx | 214.85kb | Oct 2, 2020 4:55:28 PM | Public | ||
Translated version
Torvinen--2018----EPMA-WDS-sherd-data_translated.xlsx
(174.05kb)
Data column(s) in this dataset have been associated with coding sheet(s) and translated:
|